BETALOG
Data Logging User’s Manual
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - Data Logging User’s Manual

BETALOGData Logging User’s Manual

Seite 2

2) Display number of free log records• Main display: number of free records• Secondary display: FREE• the ▼ and ▲ keys are ignored.• press the CONFI

Seite 3

6) Confirm erasure of all logged data and set to Demandmode• Main display: CLEAr• Secondary display: CNFRM• the ▼ and ▲ keys are ignored.• press the

Seite 4

4.1 Installation and RegistrationInsert the distribution CD into the drive on your computer. The installshould start automatically. If it does not,

Seite 5

Upload Data Upload all data logging runs from the gauge andshow them on the Log Upload Display described insection 4.4. The data may be exported from

Seite 6

4.3 Main DisplayThe top portion of the display contains controls to connect to a gauge,disconnect from a gauge, upload logged data, clear logged data,

Seite 7 - 3. Gauge Operation

Clearing Logged DataClick the Clear button. After confirmation of the action, all logged datais cleared from the gauge, the data logging mode is set

Seite 8

IntervalOne of the following sampling intervals:1, 2, 5, 10, or 30 seconds1, 2, 5, 10, or 30 minutes1 hourSamples/RunThe maximum number of samples to

Seite 9 - 3.3 Demand Mode

Trip range Interval samples are stored during the runonly when the pressure differential duringthe interval exceeds a maximum span orrange. Sample st

Seite 10

4.4 Log Upload DisplayThe top portion of the display lists the individual data logging runsfound in the uploaded data. To display a run's data i

Seite 11

The Export Options screen is described further under Export Options insection 4.6.To export all runs, click the Save All button. The Export Options s

Seite 12 - 4.2 Menus

BETALOGData Logging User’s Manual1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12. Description . . . . . .

Seite 13

display. Place a checkmark next to each field that is to be shown onthe display when the display mode is set to Selected Data. Loggedpressure readin

Seite 14

The selections are as follows:File TypeTXT File A formatted text file that may be printeddirectly or opened in a text editor. The rundescription fiel

Seite 15

Include FieldPlace a checkmark next to each field that is to be exported.Logged pressure readings are always exported.Insert DescriptionAn optional fi

Seite 16

There are six field values for each triple valuepressure reading: the date, the time, the averagereading, the minimum reading, the maximumreading, and

Seite 17

5.1 Single Run GraphThis template provides custom titles and a graph of the merged data.The graph vertical axis is scaled to the range of the uploaded

Seite 18

Field Include Field Insert Description Excel CellRun # or Label Yes No B3Gauge Description Yes No B5Log and Sample Type Yes No B10Interval Time Yes No

Seite 19

TRADEMARKSTrademarks or trade names are subject to state and federal lawsconcerning their unauthorized use or other infringements. The fact thatthe p

Seite 21

0200041 Rev A 10/09 www.martelcorp.come-mail: [email protected]: (603) 434-1433 800-821-0023 Fax: (603) 434-1653 Martel Electronics3

Seite 22

1. IntroductionThis Manual describes the data logging capability and operation of thepressure gauge, plus the operation of the related BetaLOG Microso

Seite 23 - 5. Excel Templates

The gauge can log pressure only for each sample, or it can logpressure and temperature for each sample. This selection applies toall runs and must be

Seite 24 - 5.1 Single Run Graph

the BetaLOG application or the gauge 'CLEAr DATA' function is usedclear the logged data in the gauge, at which time the mode is set toDemand

Seite 25 - 6. Warranty

- Trip Range, where interval samples are stored during the runonly when the pressure differential during the interval exceeds amaximum span or range o

Seite 26 - TRADEMARKS

• Sample type selection fixed at 'Last measurement made in thesample interval'.• Log pressure unit selection. The unit is selected with the

Seite 27

not logging data, or to toggle between ON and STOP if loggingdata.• press the CONFIG key to step to the next menu item.• press the ENTER key to exit c

Seite 28 - 0200041 Rev A 10/09

• Forced power off on low battery detection causes the log run tobe stopped before power is turned off.• The zero key is active and an event record (i